Cased Coil Selection Guide: What Florida HVAC Contractors Need to Know (2026)
To choose a cased coil, match three things. Capacity should cover the tonnage of the outdoor unit. Cabinet width should match the furnace and plenum it sits on. The coil and condenser should be a certified combination for the same refrigerant and metering device. Then confirm the pairing in the AHRI Directory, because the system’s SEER2 rating, and whether it meets Florida’s minimum, belongs to the matched combination.
Step 1: Match the coil capacity to the condenser
Size the system first. Florida Building Code, Energy Conservation R403.7.1 requires Manual S selection from a Manual J (or approved) load calculation and the indoor and outdoor model numbers on the submittal. Then choose a coil rated for that tonnage. iAir coils are dual-rated, covering two tonnages each (for example 3/3.5 ton), so one coil can serve either size of condenser.
Step 2: Match the cabinet width to the furnace
A cased coil sits on the furnace outlet, so the coil cabinet width should line up with the furnace cabinet and supply plenum. A mismatch means transitions and air leakage at the joint. iAir cased coils come in 14″, 17.5″, 21″ and 24.5″ widths:
| Coil | Capacity | Width | Tube | Metering | Chilly Air price |
|---|---|---|---|---|---|
| iAir 1.5/2 ton 14″ coil | 1.5/2 ton | 14″ | Aluminum | Orifice | $510.99 |
| iAir 1.5/2 ton 17.5″ coil | 1.5/2 ton | 17.5″ | Aluminum | Orifice | $554.99 |
| iAir 2/2.5 ton 14″ coil | 2/2.5 ton | 14″ | Aluminum | Orifice | $583.99 |
| iAir 2/2.5 ton 17.5″ coil | 2/2.5 ton | 17.5″ | Aluminum | Orifice | $635.99 |
| iAir 2/2.5 ton 21″ coil | 2/2.5 ton | 21″ | Aluminum | Orifice | $673.99 |
| iAir 3/3.5 ton 17.5″ coil | 3/3.5 ton | 17.5″ | Aluminum | Orifice | $753.99 |
| iAir 3/3.5 ton 21″ coil | 3/3.5 ton | 21″ | Aluminum | Orifice | $792.99 |
| iAir 3/3.5 ton 24.5″ coil | 3/3.5 ton | 24.5″ | Aluminum | Orifice | $834.99 |
| iAir 4/5 ton 21″ coil | 4/5 ton | 21″ | Copper | Orifice | $998.99 |
| iAir 4/5 ton 24.5″ coil | 4/5 ton | 24.5″ | Copper | Orifice | $1,040.99 |
Step 3: Match the metering device and refrigerant
Every iAir cased coil we list ships with an orifice (fixed) metering device. Before you install, check the outdoor unit’s installation instructions to confirm an orifice coil is approved for that condenser, which orifice size it needs, and whether a TXV is required instead. With new A2L systems, confirm the coil is approved for the refrigerant the condenser uses. An old R-410A coil isn’t automatically approved for an R-32 or R-454B condenser. See our A2L transition guide.
Step 4: Confirm the AHRI-certified combination
DOE’s Southeast standard (10 CFR 430.32(c)) is 14.3 SEER2 for split ACs under 45,000 Btu/h and 13.8 SEER2 at 45,000 Btu/h and up. The rule also says an outdoor unit with any certified combination rated below that level can’t be installed in the region. Look up your exact condenser and coil pairing in the AHRI Directory and keep the certificate with the permit paperwork. Inspectors in Florida check equipment against the submittal (see common inspection failures).
Aluminum or copper tube?
In the iAir lineup we carry, the 1.5–3.5 ton coils use aluminum tube and the 4/5-ton coils use copper tube. Tube material is fixed by the model you choose, so pick by capacity and width first.
Cased coil vs air handler
If the home has a gas furnace, the coil goes on the furnace. If it’s all-electric, a complete multi-position air handler ($1,058.99 for 3 ton) replaces the furnace-and-coil setup, with an electric heat kit for heat. Our ECM vs PSC motor guide covers air handler blower choice.
Frequently asked questions
How do I choose the right cased coil size?
Match the coil's rated capacity to the outdoor unit tonnage from a Manual J/Manual S sizing, match the cabinet width to the furnace, and confirm the condenser-coil pairing is an AHRI-certified combination.
Does the cased coil width have to match the furnace?
The coil sits on the furnace outlet, so matching the cabinet width avoids transitions and air leaks. iAir cased coils come in 14", 17.5", 21" and 24.5" widths.
Do iAir cased coils come with a TXV or orifice?
The iAir cased coils sold at Chilly Air ship with an orifice metering device. Check the outdoor unit's installation instructions to confirm the correct orifice or whether a TXV is required.
Why does the AHRI match matter in Florida?
Under 10 CFR 430.32(c), an outdoor unit with a certified combination rated below the Southeast minimum (14.3 SEER2 under 45,000 Btu/h) cannot be installed in Florida, and Florida code requires indoor and outdoor model numbers with the sizing submittal.
How much does an iAir cased coil cost?
iAir cased coils at Chilly Air are listed from $510.99 (1.5/2-ton, 14") to $1,040.99 (4/5-ton, 24.5"), before tax and shipping.
Questions about matching equipment or contractor pricing? Call or text 813-445-6228 or email orders@chillyairllc.com.
Last updated: November 21, 2026. Sources: Florida Building Code, Energy Conservation (8th ed., 2023) R403.7.1 – equipment sizing; 10 CFR 430.32(c) – DOE energy conservation standards for central AC and heat pumps; AHRI Directory of Certified Product Performance.